Changing a Robot/NETWORK 9.0 Node System from SNA to TCP/IP Protocol

Product: 
Robot/NETWORK

Changing a Node’s Communication Protocol

WARNING: Do not perform this procedure on a Host system. This procedure is for Node systems only.

To change a Robot/NETWORK Node’s protocol from SNA to TCP/IP, perform the following steps on the Node:

Note: Both the Node you are changing and its Host must be at Robot/NETWORK version 9.0.

  1. Sign on using a user profile that has the following characteristics:
    • Is a member of the user class *SECOFR.
    • Has the special authorities: *ALLOBJ, *SECADM, and *IOSYSCFG.
    • Has Limit Capabilities set to *NO.
  2. Make sure that no users are using Robot/NETWORK and that Robot/NETWORK has ended.
  3. Enter the following command and press Enter:
  4. ADDLIBLE RBTNETNODE

  5. Enter the following command and press Enter:
  6. CALL RBNNCLEAN

  7. Enter the following command and press F4 to display the command prompt:
  8. RBTNETNODE/RBNCFGNODE

  9. From the command prompt, enter the following values:
  10. Communication Type TCPIP
    Name The current system name of the Robot/NETWORK Host.
    Password The Robot/NETWORK password. (If you do not know the password, ask
    your Network administrator for the Host RBTNETPT password.)
    IP Address The Host’s TCP/IP address.

 

Updated July 10, 2000