November Q&A Column
How do I copy a list of reports from one recipient to another in Robot/REPORTS?
Robot/REPORTS (7.19 or higher) includes the REPCPYDST command to copy distribution from one recipient to another. This command copies both the distribution and its related history, so the recipient sees reports processed in the past, as well as receiving future reports. You must supply three parameters to the command:
- From Recipient (FROM): Enter the name of the report recipient whose report list will be copied.
- To Recipient (TO): Enter the name of the report recipient who will receive the reports.
- Copy Distribution List reports (COPYDIST): Specify whether to copy all of the reports the From recipient receives, including reports distributed from distribution lists.
- Y (Yes): Include the reports the From recipient receives from distribution lists.
- N (No): Exclude the reports the From recipient receives from distribution lists.
Here are some other things you should know about this command:
- You cannot use the name of a distribution list for either the To or From recipient.
- The REPCPYDST command produces a report (REP746) listing which reports will be distributed to the To recipient.
If I have the Secure Socket Layer (SSL) enabled in Client Access, can I use
SEQUEL ViewPoint?
Yes, as long Client Access Certificates have been established for the Sign-On Server, Database Server, Remote Command, Central Server, Data Queue Server, and DDM/DRDA Server. Run the iSeries Navigator SSL Connection test. If it is successful for all but the Network File application, Print application, and Telnet application, you should be good to go.